Connect your charge controller to the battery with a pair of Renogy high-quality copper tray cables. Specialized with battery rings on one end for effortless connection to your battery and exposed stranded wire on the other end to lead directly into your charge controller, this wire makes the system set up as easy as can be!
1. Solar charge controller
1 AC Terminal Block
2. Battery
3. Battery cables (with terminal rings on one end and stripped at the other.
4. Fuse set with cable
5. Wire crimper and screwdriver
Insert the stripped end and screw the terminal shut. All Renogy Charge Controller have the battery terminals labeled with a battery icon"BATT".
The Renogy ANL fuse will protect the charge controller, wire, and battery from over-current. The fuse set and fuse cable are available from Renogy.
Connect the negative battery cable to the negative battery terminal and the positive cable to the positive terminal.
Check the installation instructions in your charge controller’s manual and set up the battery type correctly.
Double check all your connections to make sure that none are loose.
- If you have any questions regarding this product, please call us at 1 (909) 287-7111 or or contact us for troubleshooting assistance.
- More questions about your off-grid power system? Learn more from Renogy Learning Center!
Package Includes
Renogy Solar Tray Cables / one pair 1 x pair
|
Battery to Charge Controller Tray Cables for 3/8 in Lugs | |||
---|---|---|---|
RENOGY 4AWG WIRE COPPER SOLAR TRAY CABLES FOR CONNECTING CHARGE CONTROLLER TO BATTERY (A PAIR) | |||
Length | 8FT/16FT (20.3cm / 40.6cm) | ||
Gauge (Wire Size) | 4AWG / 21.2mm² | ||
Terminal Size | 3/8 in Lugs (M10) | ||
Max. Current | 95A | ||
Rating Voltage | 600/1000V | ||
Temperature | -40°F to +185°F | ||
RENOGY 8AWG WIRE COPPER SOLAR TRAY CABLES FOR CONNECTING CHARGE CONTROLLER TO BATTERY (A PAIR) | |||
Length | 8FT/16FT (20.3cm / 40.6cm) | ||
Gauge (Wire Size) | 8AWG / 8.4mm² | ||
Terminal Size | 3/8 in Lugs (M10) | ||
Max. Current | 55A | ||
Rating Voltage | 600/1000V | ||
Temperature | -40°F to +185°F | ||
RENOGY 10AWG WIRE COPPER SOLAR TRAY CABLES FOR CONNECTING CHARGE CONTROLLER TO BATTERY (A PAIR) | |||
Length | 8FT/16FT (20.3cm / 40.6cm) | ||
Gauge (Wire Size) | 10AWG / 5.3mm² | ||
Terminal Size | 3/8 in Lugs (M10) | ||
Max. Current | 30A | ||
Rating Voltage | 600/1000V | ||
Temperature | -40°F to +185°F | ||
RENOGY 12AWG WIRE COPPER SOLAR TRAY CABLES FOR CONNECTING CHARGE CONTROLLER TO BATTERY (A PAIR) | |||
Length | 8FT/16FT (20.3cm / 40.6cm) | ||
Gauge (Wire Size) | 12AWG / 3.3mm² | ||
Terminal Size | 3/8 in Lugs (M10) | ||
Max. Current | 20A | ||
Rating Voltage | 600/1000V | ||
Temperature | -40°F to +185°F | ||
WARRANTY INFORMATION | |||
Accessories | 1-year material warranty |
1. Current flow in amps. Pick a wire gauge that is big enough to carry the amount of current (in amps) that will be flowing through your system. For instance, if you have one of Renogy 40Amp charge controllers, we would recommend using an 8AWG wires.
2. Charge controller terminals. Some charge controllers have small terminals that won’t accept wire thicker than a certain gauge. Check to see if compatible wire gauges are listed in your charge controller’s manual.
There are three different locations that we recommend installing fuses or breakers: first, between the charge controller and battery bank, second, between the charge controller and solar panels, and third would be between the battery bank and inverter.
To determine the fuse size needed between the charge controller and battery bank you simply match the amperage rating on the charge controller. For instance, if you have one of our 40Amp charge controllers, we would recommend using an 40Amp fuse.